DoCHEng symbolDoCHEngDriven by Curiosity
← All engineering tools

Free screening calculation

Pump power

Estimate shaft power from flow, head, density and pump efficiency.

Equation and assumptions

Pshaft = ρ g Q H / η; QSI = Q / 3600; η = efficiency / 100

Steady incompressible flow. Pump efficiency excludes motor/drive losses. Head must already represent the required total pump head. g = 9.80665 m/s².

The source below supports the underlying unit, mass-balance or hydraulic method. It does not validate this software or a proposed engineering design.

U.S. Department of Energy — Fluid flow fundamentals

Use for preliminary screening. Verify inputs, physical assumptions and results independently before engineering design, operational changes or safety decisions.

Continue research in DoCHEng Desk